Home About Case Studies Products Support Contact Site Map

DataWeb

Measuresoft Logo

ScadaPro I/O Drivers

 

 

Typical applications

  • Process plant auxiliary monitoring
  • Building services
  • Environmental monitoring
  • Energy management
  • Utility monitoring (gas, water, etc.)
  • Bulk storage management

 

 Flexible, reliable communication...

Data is transferred from DataWeb modules via TCP/IP on Ethernet, or serial modem (PSTN,GSM,ADSL or radio). If the link is interrupted, error detection in the DataWeb Control Centre software will initiate re-dialling until the data has been properly aquired from the module.

...with intelligence

When real-time data is required - for example, if a mimic with a live update is being viewed - DataWeb Control Centre establishes and maintains the data link for as long as data is being accessed and displayed .

Automatic data transfer

Stored data is transferred from the modules at scheduled times or regular intervals. For serial connections, the dial-up connection is closed when the data has been successfully transferred. On completion of the transfer, the data in the module can be deleted if required.

Complete data integration 

Data from the modules is written into the main Orchestrator database, and new data can be appended to the existing files, or replace them.

The software can also integrate data from a wide range of other acquisition modules and systems, including MSL's DataScan and Solo modules.

Perfect timing...

The internal DataWeb clocks can be synchronised to the main system clock to ensure that the sequence of data events is properly recorded.

Expansion unlimited

DataWeb Control Centre is completely scaleable; starting from the very affordable entry level package covering a single DataWeb module, systems can be expanded up to 140 modules per location with no lilit to the number of locations.

Alarm handling

When an alarm email is detected from any of the DataWeb modules, the software immediately dials up and interrogates the module location for additional information. Based on this, a variety of sutable actions can be configured, including sending further messages by email or SMS.

Password Protection

All data is protected from unauthorised access using a password system.

Module configuration

DataWeb Control Centre software provides facilities for configuring all acquisition and alarm options for every DataWeb module, using the familiar on - screen dialog box entry system.

Alternative internet access

Local access to Data Web module data - for diagnostic or IP configuration purposes, for example - is available via the module's integral internet server.

DataWeb modules provide remote, rugged data acuisition and logging facilities. 8 and 16 analog channel versions, with configurable hi/lo alarm levels, are available, each with 8 additional digital channels can be configured for pulse counting in metering applications.

Access to DataWeb data is via Ethernet (TCP/IP) or serial link. Data can be accessed live, and there are General and Event Loggers which can store over 12,000 readings at up to 10 readings/s. Data is accessed using ftp or http.